Flumasys logo
En flag English Cs flag Čeština De flag German
Variant codes M3AA


← back


Code/Variants 

Frame size

56 63 71 80 90 100 112 132 160 180 200 225 250
Administration
+531  Sea freight packing. - -
+601  Special Sea freight packing - - - - - - - -
Balancing
+052  Vibration acc. to Grade A (IEC 60034-14).
+426  Half key balancing.
Bearings and Lubrication
+037  Roller bearing at D-end. - - - - - - - -
+039  Cold-resistant grease. - -
+040  Heat-resistant grease. - -
+041  Bearings regreasable via grease nipples. - - - -
+042  Locked D-end
+043  SPM compatible nipples for vibration measurement. - - - - - - - -
+057  2RS bearings at both ends. -
+188  63-series bearing in D-end. - - - -
+194  2Z bearings greased for life at both ends
+195  Bearings greased for life
+593  Bearings grease suitable for food and beverage industry. - -
+781  Lubrication plate put aside - - - - - - - -
+795  Lubrication information plate - - - - - - - -
+798  Stainless steel grease nipples. - - - - - - - -
Brakes
+086  Reconnection of brake for separate ac supply. - - - - - - -
+088  Brake with mechanical release. - - - - - - -
+288  Brake motor with voltage code S for the motor and separate supply of
the brake for voltage corresponding to code D.
- - - - - - -
+289  Brake motor with voltage code D for the motor and separate supply of
the brake for voltage corresponding to code S.
- - - - - - -
+298  Brake motor for 460V with voltage code S and D - - - - - - - - -
+843  DC Brake. (Sizes 71-132 available as premodified motors with 843) - - - - -
Branch standard designs
+178  Stainless steel / acid proof bolts.
+210  Special electric design (SEL design) - - - - - - - - - - -
+217  Cast iron D-end shield (on aluminum motor). - - - -
+232  Cast iron N-end shield (on aluminium motor) - - - - - - - -
+425  Corrosion protected stator and rotor core. - -
Cooling system
+046  Two-directional fan.
+053  Metal fan cover. - -
+068  Light alloy metal fan. - -
+183  Separate motor cooling (fan axial, N-end). - -
+205  Non metalic fan.
+792  Metal fasteners for fan cover.
Documentation
+141  Binding 2D main dimension drawing.
Drain holes
+065  Plugged existing drain holes. - - - - - - - -
Earthing Bolt
+067  External earthing bolt. -
○ = Included as standard │ ● = Available as option │  - = Not applicable














Code/Variants 
Frame size
56 63 71 80 90 100 112 132 160 180 200 225 250
Hazardous Environments
+335 Ex t, Dust group III B T125C Dc, IP5X (non-conductive dust) acc. IEC/EN60079-31. - - - - - - - -
+336 Ex t, Dust group III C T125 Db, IP6X (conductive dust) acc. IEC/EN60079-31. - - - - - - - -
+338 Rated for gas or dust, Ex ec IIC T3 Gc / Ex tc IIIB T125C Dc (non-nocductive dust), IP5X. - - - - - - - - -
+339 Rated for gas or dust, Ex ec IIC T3 Gc / Ex tc IIIC T125C Dc (conductive dust), IP6X. - - - - - - - - -
+456 Ex ec IIC T3 Gc acc. IEC/EN 60079-7 with certificates. - - - -
Heating elements
+450 Heating element, 100-120 V. - -
+451 Heating element, 200 - 240 V. - -
Marine
+096 Fulfilling Lloyds Register of Shipping (LR) requirements, without certificate (non-essential duty only). - -
+186 Fulfilling Det Norske Veritas (DNV) requirements, without certificate. - -
+492 Fulfilling Registro Italiano Navale (RINA) requirements, without certificate. - -
+493 Fulfilling China Classification Societies (CCS) requirements (Beijing), without certificate. - -
+496 Fulfilling Bureau Veritas (BV) requirements, without certificate(non-essential duty only). -
+675 Fulfilling American Bureau of Shipping (ABS) requirements, without certificate (non-essential duty only). - -
Mounting arrangements
+007 IM 3001 flange mounted, IEC flange, from IM 1001 (B5 from B3). - - - - - - - -
+008 IM 2101 foot/flange mounted, IEC flange, from IM 1001 (B34 from B3). - - - -
+009 IM 2001 foot/flange mounted, IEC flange, from IM 1001 (B35 from B3).
+047 IM 3601 flange mounted, IEC flange, from IM 3001 (B14 from B5). - - - -
+048 IM 3001 flange mounted, IEC flange, from IM 3601 (B5 from B14). - - - - - - -
+066 Modified for specified mounting position differing from IM B3 (1001), IM B5 (3001), B14 (3601), IM B35 (2001), IM B34 (2101).
+200 Flange ring holder. - - - - - - -
+223 Flange ring FF 115. - - - - - - - - - -
+224 Flange ring FT 115. - - - - - - - - - -
+226 Flange ring FF 130. - - - - - - - -
+227 Flange ring FT 130. - - - - - - - -
+233 Flange ring FF 165. - - - - - - - -
+234 Flange ring FT 165. - - - - - - - -
+243 Flange ring FF 215. - - - - - - - - - - -
+253 Flange ring FF 265. - - - - - - - - - - - -
+255 Flange FF 265. - - - - - - - - - - - -
+260 Flange FT 115. - - - - - - - - - - - -
Painting
+114 Special paint color, standard grade.
+714 Customer painting specification - - - - - - -
Protection
+005 Protective roof.
+072 Radial seal at D-end. Not possible for 2-pole , 280 and 315 frames. - -
+074 Degree of protection IP55.
+158 Degree of protection IP65. - -
+250 Degree of protection IP66. - -
+403 Degree of protection IP56. - -
+784 Gamma-seal at D-end. - - - -
○ = Included as standard │ ● = Available as option │  - = Not applicable














Code/Variants 
Frame size
56 63 71 80 90 100 112 132 160 180 200 225 250
Rating & instruction plates
+002 Restamping voltage, frequency and output, continuous duty.
+003 Individual serial number.
+004 Additional text on std rating plate (max 12 digits on free text line). - -
+095 Restamping output (maintained voltage, frequency), intermittent duty.
+098 Stainless steel rating plate. - -
+126 Tag plate.
+135 Mounting of additional identification plate, stainless steel. - -
+138 Mounting of additional identification plate, aluminium. -
+159 Additional plate with text “Made in    ”.
+160 Additional rating plate affixed. - - - -
+161 Additional rating plate delivered loose.
+162 Rating plate fixed to stator
+163 Frequency converter rating plate. Rating data according to quotation. - - -
+181 Rating plate with ABB standard loadability values for VSD operation. Other auxiliaries for VSD operation to be selected as necessary. - -
+332 Baldor Catalogue #.
Shaft & rotor
+164 Shaft extension with closed keyway
Standards and Regulations
+208* Fulfilling Underwriters Laboratories (UL), listed requirements. - - -
+331 Motor not for sale for use in EU. - -
+509* Fulfilling US Integral Horsepower Motor Rule (IHP). - - -
+538 CE mark - -
+540* China energy label. - - -
+543 Australian MEPS. - - -
+544 Australian HE MEPS - - -
+586 UKCA mark - -
+598 Universal motor - - - - - - -
+687 Fulfilling energy efficiency requirements for Canada - - - - - - -
Stator winding temperature sensors
+122 Bimetal detectors, break type (NCC), (3 in series), 150 ºC, in stator winding. - -
+436 PTC - thermistors (3 in series), 150 ºC, in stator winding.
+445 Pt100 2-wire in stator winding, 1 per phase. - - - - - - -
Terminal box
+015 Motor supplied in D connection. - -
+017 Motor supplied in Y connection. - - - -
+018 Small terminal box - - - - - - - -
+019 Larger than standard terminal box. - - - - - - - - - -
+021 Terminal box LHS (seen from D-end). - - - - - - - - - -
+022 Cable entry LHS (seen from D-end). - - - - - - - - - -
+180 Terminal box RHS (seen from D-end). - - - - - - - - - -
+230 Standard metal cable gland. - -
+375 Standard plastic cable gland. - - - - - - -
+465 Terminal box on top.
+731 Two standard metal cable glands. - - - - - - - -
+738 Prepared for metric cable glands.
Testing
+145 Type test report from a catalogue motor, 400V 50Hz.
+148 Routine test report.
Variable speed drives
+701 Insulated bearing at N-end. - - - - - - - -
+704 EMC cable entry. - - - -
Y/D starting
+023 6 terminals (for Y/D start, single speed), in terminal box.
○ = Included as standard │ ● = Available as option │  - = Not applicable
* Valid only for registered motors (Motor type M3AA with generation K)


← back